Fire Incident Happen In World Trade Center Environmental Sciences Essay

Last Updated: 25 Jun 2021
Pages: 11 Views: 233
Table of contents

1. Introduction

High-rise edifice has become big portion of people and assets exposed, particularly for the big figure of high-rise edifices presently building in Asia and Middle East. Harmonizing to Hall.J.R. , ( 2005 ) reference about tower block edifice has lower hazard of fire per unit floor country. So this thought has brought and changed human perceptual experience advanced about building engineering. Mention to US NFPA 101 Life Safety Code, the edifices which have height more than 23m defined as tower block edifice. When constructing construct higher and higher, fire safety demand to be concern because it will impact the deliverance mission and fire combat operation. Evacuation procedure is of import assist people escape from edifice.

2. Issue Statement

Order custom essay Fire Incident Happen In World Trade Center Environmental Sciences Essay with free plagiarism report

feat icon 450+ experts on 30 subjects feat icon Starting from 3 hours delivery
Get Essay Help

In recent old ages, fire onslaught in high rise edifice has become the common issue which cause many civilian deceases and injured. Civilians who stayed in high rise edifice were unable to get away because they located at high degree from the land. On behalf the fire incident happen, fright besides has caused the job which makes them unable to get away. Although fire exigency issue are provided, it is excessively slow for civilian staying in the top floors of the edifice to get away. The opportunity of them to get away is low. Another job is trouble for fire combatants to make the upper floors. For illustration, the highest fire truck ladder can merely extends to the eight floors. In order to snuff out fire above that point, fire combatants must mount up many of stepss along with fire hosieries and other heavy equipment.

High-rise edifices are designed to be safe. When come to many civilian stay at tall edifice, exigency response is become more hard to evacuate civilians out of the edifice. What tallness is considered tower block? Refer to paragraph 3.3.28.7 of the Life Safety CodeA® , 2006 edition, defines a high-rise edifice as a edifice more than 75 pess ( 23 metres ) in tallness which measured from the lowest degree land floor entree to the floor of the highest of the edifice.

Earlier to 1999, the National Fire Incident Reporting System ( NFIRS ) coded edifice tallness in scopes which considered as tower block such as 7-12 narratives, 13-24 narratives, 25-49 narratives, and 50 narratives or more. Get downing in 1999, NFIRS Version 5.0 permits the exact tallness to be recorded. It is besides possible to separate between height above land and entire tallness. In maintaining with the Life Safety Code definition, a tallness above land of seven or more narratives is used to specify tower block from 1999 on.

There are many instances related to fire incident. For illustration, the incident go on on Twin Towers of the World Trade Center in New York City wholly collapsed merely over one hr after fires raged in them upon the clang of two aeroplanes into them on 11 September 2001. This entire incident caused 2795 dead. Harmonizing to Craven.J. , ( 2001 ) The causes of edifices prostration was due to terrible weakening of the supporting strength of the towers ' steel-based supporting construction under impact from terrorist planes and utmost heat. Besides, the high-rise flat fire in Shanghai on15 November 2010 has become attending for people around the universe. This incident has taken 53 people life and injured 70 casualties. This incident was caused by the flicker during welding work. ( YeinJee 's Asiatic Journal, 2010 ) Furthermore, there is another fire incident happen in Busan on October 2010. Based on the study, there are no casualties were reported as most occupants were dispersed after the fire broke out. Fire combatants rescued 31 occupants, four of casualties were sent to the infirmary for intervention. Based on the probe, people suspect the cause happen from the fire started at the refuse room on the 4th floor which is extremely flammable wall stuff and strong air currents seemingly fuelled the fire. Based on incidents highlighted, the fire safety design needs to be considered more critically for all the high rise edifice. ( Koreabridge, 2010 )

3. Research Hypothesis

This research survey focused on two key countries which are the demand of fire safety shelter design needed in high rise edifice and to measure the consciousness of residents about fire safe shelter. Fire safe shelter is designed as safety floor which can let residents to remain for emptying. Harmonizing to Snyder.L. , ( 2009 ) mentioned about the shelter in topographic point is designed to let residents to withdraw to a safe country which can protect against heat and fume. That country can be used to help the orderly mercantile establishment of residents, hold residents until first respondents can deliver them, or keep residents until the menace is eliminated. Ever more, refuge countries provided bipartisan communicating systems to reach with first respondents.

Recently, there are several Asiatic states such as China and Singapore has developed as many sky scrapers. During the designing procedure, tall edifices must be provided with refuge floors every 20 to 25 floors. These are normally mechanical floors ( no usually occupied infinite ) with at least 50 % of the floor country configured as an country of safety ( 2-hr separations to equipment infinites, no fuel burden, infinite to keep all residents of the floors between refuge floors at 0.3 M2 or 3 ft2per individual ) . They are required to be unfastened on two opposite sides so that fume will non roll up. Refuge floors provide a protected infinite for residents to rest or to expect aid, or to traverse between staircases. ( Code of Practice for the Provision of Means of Escape in Case of Fire, Part II, Section 21 Refuge Floors, Hong Kong Building Authority, 1996 )

Refer to Meacham.B. , ( 2006 ) mentioned about demands for refuge floors are comparatively new and are presently found in merely a few edifices. No existent emptyings have occurred but there is some experience from drills that indicates there may be a job when people reach a refuge floor and make up one's mind to wait at that place instead than go oning the emptying.

Indeed, the consciousness of residents who stayed at high rise edifice should be considered. Each resident who stays in tower block should responsible to cognize where the safety topographic point is. Owner of the edifice should supply fire safety program and information which can steer residents to get away during fire incident. Fires Safety Drill should be organize by the fire section which can assist people more understand on what state of affairs and to protect themselves. During the drill procedure, occupants gather on the refuge floor such that extra geting residents can non come in. This is a drill procedure where the residents know they are non in danger and that they will be returning to their floor after the drill. Presently, the World Financial Center building in Shanghai incorporates refuge floors and besides uses two observation lifts running on the exterior of the ace columns on diagonal corners of the edifice. These lifts were originally designed to supply express service merely to the observation deck on the top floor. These observation lifts were modified to halt at each of the safety floors to be used for occupant emersion in fires. Alternatively of people need to go from 25 floors to land floor, the better manner is utilizing the closest safety floor even if it was above your place.

4. Aim

The purpose of this research is to entree the demand for fire safety means in high rise edifices.

5. Aims

  1. To detect how best to better fire safety by utilizing fire safe shelter.
  2. To suggest solution on how to incorporate the fire safety design in high rise edifice.

6. Scope

This research discussed the design of shelters to protect against fire onslaught. The design of such shelters requires attending to jobs such as the figure of residents remaining or working in such edifice and besides the weight of the edifice which affected the design of shelter. The used of this fire safety system can take to better protection in order to cut down hazard of danger from residents. Besides, the counter measured for high rise edifice fire besides needs to be considered to cover with big hazard as follows,

  1. Fire safe shelter design in tower block edifice
  2. Emptying

7. Methodology

In order to accomplish the aims that have been stated, the research was carried out in measure by stairss. First of all, place the aims and range needed for this research. Secondly is followed by carry oning literature reappraisal about issue on fire incident happen in high rise edifice and the map of fire safety shelter presently use in the tower block edifice. This procedure helped in better apprehension on the research subject and integrated the cognition to the proposed topic. Besides, professional interviews with the designer and applied scientist besides conducted related to the fire safety shelter in safety design.

8. Literature Review

8.1 Issues ( Case Study )

  1. Fire incident happen in World Trade Center in New York City
  2. Fire incident happen in high-rise flat in Shanghai
  3. Degree centigrades: UsersAcerDownloadsworld-trade-center-2nd-attack2-9-11-01.jpg
  4. Degree centigrades: UsersAcerDownloads11 ( 1 ) .jpg
  5. Beginning from Energy Matters ( 2012 )
  6. Beginning from China stillness ( 2010 )

Harmonizing to figure 1, this fire incident was happened on 11 September 2001 in New York City. The United States has faced the cruelest terrorist onslaught in history. Thousands of citizens have been killed and many more injured. This incident has shocked and overwhelmed by the monolithic loss in lives and belongings. Everyone of the citizen in there feels driven to make something to react to the calamity happened.

This twin tower of WTC has approximately 417 and 415 metres height. Along with the 110 floors Twin Towers were destroyed or severely damaged, including WTC edifices 3 through 7 and St. Nicholas Greek Orthodox Church. The North Tower, South Tower, the Marriott Hotel ( 3 WTC ) and 7 WTC were wholly destroyed. The U.S. Customs House ( 6 World Trade Center ) , 4 World Trade Center, 5 World Trade Center, and both prosaic Bridgess linking edifices were badly damaged. The Deutsche Bank Building on 130 Liberty Street was partly damaged and demolished subsequently. The two edifices of the World Financial Center besides suffered harm.

The incident happened due to the impact of plane clang. A high monolithic detonation created highly high temperature which has weakened the strength of steel beads and increased warp. Mention to Craven.J. , ( 2001 ) has mentioned about the twin towers had redundant design which means if one edifice fail, another edifice carries burden. This twin towers had entire 244 columns each around the cardinal nucleus. Although there are some column damaged, but others could stay support. Due to the go oning fire combustion, the fire spread from one portion to another portion which has weakened floors and began to fall in. The crashed floor increased the impulse which has caused the edifice could non prolong the weight and collapsed wholly. Although the deliverance mission was conducted, but the accomplishments and engineering during current twelvemonth was stilled non in advanced, so the emptying mission was failed and many citizens were killed due to enable to get away.

Figure 2 has showed another fire incident happened in Shanghai. This incident happened on 15 November 2010 at Jing An territory under redevelopment. This calamity has taken 49 people life. Harmonizing to Shanghai News ( 2010 ) has discussed about the fire happened was caused by unaccredited welders improperly runing their equipment and enkindled fire to the staging and light plastic webs which is extremely flammable. The fire started firing at the roof and continued spread the fire to plastic webs around the edifice.

Based on the issues have been discussed, fire safety is critical of import to guarantee residents who stayed in tower block edifice are protected. In order to minimise the hazard, fire safe shelter is strongly recommended to plan in tower block edifice. This design may alter to better state of affairs when fire happen.

8.2 Refuge floor ( Fire safe shelter )

Refuge floor is a particular design recommended to put in in tower block edifice to protect residents for temporarily gather and delay for evacuate in instance of fire. Based on research inquiry, refugee floor is explained in general. Refuge floors should be installed in all edifices which exceed 25 floors in tallness. Mention to Hong Kong fire section, all refuge floors should follow with the demands as specified in the `` Provision of Means of Escape in Case of Fire 1996 '' published by the Building Department.

In order to put in refuge floor, demands should purely follow. First is no occupied adjustment or nearby mechanical works room, except fire service H2O armored combat vehicles and affiliated fire service installing works room, at the same degree as the safety floor. Second, the country for safety should non be less than 50 % of the entire gross floor country of the safety floor and height non less than 2300mm. Third, the minimal dimension of the country for safety should be at least 50 % greater than the breadth of the widest stairway go throughing through the refuge floor. Fourth, the country for safety should be separated from the balance of the edifice in conformity with the demands in the Code of Practice for Fire Resisting Construction published by the Buildings Department. Continue by, the country for safety should be open-sided above safe parapet tallness on at least two opposite sides to supply equal cross airing: the unfastened sides should follow with the demands in the Code of Practice for Fire Resisting Construction. Next, any stairway passing through a refuge floor should be discontinued at such degree so that the issue path is diverted to go through over portion of the refuge country before it is continued to go out downwards. Furthermore, every portion of the country for safety should be provided with unreal illuming supplying a horizontal luminosity at floor degree of non less than 30 lx and backed up by an exigency illuming system supplying a horizontal luminosity at floor degree of non less than 2 lx. The design of the exigency illuming system should follow with the Code of Practice for Minimum Fire Service Installations and Equipment. Furthermore, a refuge floor should be provided with such fire service installing and equipment as may be required by the Director of Fire Services. Other than that, a safety floor ( other than a roof ) should be served by a fireman 's lift. The lift doors should non open onto the refuge floor in normal operation and should be locked at all times until automatically released on propulsion of the fireman 's switch and eventually is the notices and directional marks should be provided at each floor. ( Fire Services Department, 2012 )

8.3 Emptying

Presently, the fire and life safety systems installed in high-rise edifices including automatic fire sprinkler protection, are designed to command a fire and hence lessen the demand to evacuate all residents. In a typical scenario, the residents of the fire floor and the floors instantly above and below it should instantly utilize the issue stairs to fall to a floor degree that is at least several floors below the fire floor, and await farther direction from safety functionaries. Harmonizing to National Safety Council reference about successful and efficient emptying depends on complete preplanning, organisation, and supervising. Planing should carry on based on basic rule. First is constructing emptying organisation. Second is emptying policy and programs. Third is sensing and coverage based on fire or jeopardy. Follow by emptying plan coordination is about motion and emptying. Next is communicate to direct motion and emptying and last is review and rating.

9. Discussion

After the literature reappraisal has been conducted, fire safety is strongly recommended to better in order to cut down hazard of decease and hurt. Height has caused the job when the tower block edifice caught fire due to natural catastrophe or human carelessness. Fire safe shelter has been introduced to guarantee the residents can remain from fire onslaught and the possibility to get away from the incident in the shortest clip. Based on this circumstance, the developer should see on the fire safety system in a high rise edifice. Due to the tallness of a high rise edifice, it causes the residents unable to get away straight from the edifice which means they will necessitate the aid from the fire brigade for emptying. Before they can get away from the incident, the design of fire safety shelter known as refuge floor can supply a safe country to the residents. Emptying program should work with refuge floor in order to evacuate the residents out of edifice in a shortest clip. Beside, the consciousness on the fire safety system should earnestly concentrate to all the residents of high rise edifice to guarantee they gain the cognition which can protect them in instance of fire.

10. Decision

From this research, tallness is the issue which need to concentrate and see on the developing a tower block edifice. When fire incident happen, first thing the residents need to make is make n't panic. They should follow direction move to the safety floor and delay for evacuate mission. Therefore, an effectual fire safety system is of import to do certain an equal and effectual communicate system to all the floors. Residents may hold better protection to cut down the hazard to zero.

Cite this Page

Fire Incident Happen In World Trade Center Environmental Sciences Essay. (2018, Aug 18). Retrieved from https://phdessay.com/fire-incident-happen-in-world-trade-center-environmental-sciences-essay/

Don't let plagiarism ruin your grade

Run a free check or have your essay done for you

plagiarism ruin image

We use cookies to give you the best experience possible. By continuing we’ll assume you’re on board with our cookie policy

Save time and let our verified experts help you.

Hire writer