Two Peg Test is a surveying operation carried out to determine whether the leveling bubble and telescope line of sight are parallel.

Objective

Order custom essay Two Peg Test with free plagiarism report

feat icon 450+ experts on 30 subjects feat icon Starting from 3 hours delivery
Get Essay Help

Peg Test is a surveying operation carried out to determine if the leveling bubble (bubble axis) and telescope line-of-sight (line of collimation) are parallel.

Tools

  • Dumpy level
  • Tripod Staff
  • Tape Bubble staff

Field Work Procedure

  1. Each group is required to perform a peg test to check the instrument.
  2. Each person in the group is record the results of the Peg Test in their own field book.
  3. Set out and mark on the ground (with wooden pegs driven into the ground) two point some 15 m apart.
  4. Instrument is set up midway between two point A and B.
  5. Staff is read on each staff point A and point B and the height difference is calculated. Made sure the bubble staff is center
  6. Next, instrument is moved about 5m behind the point B. nd staff at point A and point B is read. vii. Record the data.

Result

Point A1 – point B1 =1. 312 – 1. 310 =0. 002m Point A2 – point B2 =1. 239 – 1. 238 =0. 001m STN 1 – STN 2 = 0. 002 – 0. 001 =0. 001m =1mm ? < ± 2mm

Analysis

The error is ±2mm so it can be accepted. The instrument is in good condition and can used in field work.

Conclusion

The instrument can be determined the leveling bubble (bubble axis) and telescope line-of-sight (line of collimation) are parallel.

Related Questions

on Two Peg Test

What is the purpose of a PEG test?
The purpose of a PEG test is to measure the amount of gastric emptying, or how quickly food moves from the stomach to the small intestine. It is used to diagnose and monitor conditions such as gastroparesis, which is a disorder that affects the normal movement of food through the digestive system.
What is two peg test for permanent adjustment?
The two peg test for permanent adjustment is a method used to measure the accuracy of a person's hearing. It involves the person listening to two tones of different frequencies and adjusting the volume of each tone until they are equal in loudness. This test is used to determine the degree of hearing loss and to adjust hearing aids for optimal performance.
How to carry out a collimation check two peg test for a level instrument?
To carry out a collimation check two peg test for a level instrument, first set up two pegs at a known distance apart. Then, place the level instrument on the first peg and adjust the bubble until it is centered. Move the instrument to the second peg and adjust the bubble again until it is centered. If the bubble is centered on both pegs, the instrument is collimated correctly.
What is the maximum recommended distance between the two pegs for a two peg test?
The maximum recommended distance between the two pegs for a two peg test is typically between 18 and 24 inches. This distance allows for a comfortable reach for the participant while still providing an accurate measure of their coordination and balance.

Cite this Page

Two Peg Test. (2017, Apr 21). Retrieved from https://phdessay.com/two-peg-test/

Don't let plagiarism ruin your grade

Run a free check or have your essay done for you

plagiarism ruin image

We use cookies to give you the best experience possible. By continuing we’ll assume you’re on board with our cookie policy

Save time and let our verified experts help you.

Hire writer