  • Provide background information about FDDI technology.
  • Explain how FDDI works.
  • Describe the differences between FDDI and Copper Distributed Data Interface (CDDI).
  • Describe how CDDI works.
  • Fiber Distributed Data Interface

Introduction

The Fiber Distributed Data Interface (FDDI) specifies a 100-Mbps token-passing, dual-ring LAN using fiber-optic cable. FDDI is frequently used as high-speed backbone technology because of its support for high bandwidth and greater distances than copper.

It should be noted that relatively recently, a related copper specification, called Copper Distributed Data Interface (CDDI), has emerged to provide 100-Mbps service over copper. CDDI is the implementation of FDDI protocols over twisted-pair copper wire. This chapter focuses mainly on FDDI specifications and operations, but it also provides a high-level overview of CDDI. FDDI uses dual-ring architecture with traffic on each ring flowing in opposite directions (called counter-rotating). The dual rings consist of a primary and a secondary ring.

During normal operation, the primary ring is used for data transmission, and the secondary ring remains idle. As will be discussed in detail later in this chapter, the primary purpose of the dual rings is to provide superior reliability and robustness.

FDDI was developed by the American National Standards Institute (ANSI) X3T9. 5 standards committee in the mid-1980s. At the time, high-speed engineering workstations were beginning to tax the bandwidth of existing local-area networks (LANs) based on Ethernet and Token Ring. A new LAN media was needed that could easily support these workstations and their new distributed applications. At the same time, network reliability had become an increasingly important issue as system managers migrated mission-critical applications from large computers to networks.

FDDI was developed to fill these needs. After completing the FDDI specification, ANSI submitted FDDI to the International Organization for Standardization (ISO), which created an international version of FDDI that is completely compatible with the ANSI standard version. FDDI Transmission Media FDDI uses optical fiber as the primary transmission medium, but it also can run over copper cabling. As mentioned earlier, FDDI over copper is referred to as Copper-Distributed Data Interface (CDDI). Optical fiber has several advantages over copper media.

In particular, security, reliability, and performance all are enhanced with optical fiber media because fiber does not emit electrical signals. A physical medium that does emit electrical signals (copper) can be tapped and therefore would permit unauthorized access to the data that is transiting the medium. In addition, fiber is immune to electrical interference from radio frequency interference (RFI) and electromagnetic interference (EMI). Fiber historically has supported much higher bandwidth (throughput potential) than copper, although recent technological advances have made copper capable of transmitting at 100 Mbps.

Finally, FDDI allows 2 km between stations using multimode fiber, and even longer distances using a single mode. FDDI defines two types of optical fiber: single-mode and multimode. A mode is a ray of light that enters the fiber at a particular angle. Multimode fiber uses LED as the light-generating device, while single-mode fiber generally uses lasers.

Internetworking Technologies

Because these modes of light enter the fiber at different angles, they will arrive at the end of the fiber at different times. This characteristic is known as modal dispersion. Modal dispersion limits the bandwidth and distances that can be accomplished using multimode fibers. For this reason, multimode fiber is generally used for connectivity within a building or a relatively geographically contained environment. Single-mode fiber allows only one mode of light to propagate through the fiber. Because only a single mode of light is used, modal dispersion is not present with single-mode fiber.

Therefore, single-mode fiber is capable of delivering considerably higher performance connectivity over much larger distances, which is why it generally is used for connectivity between buildings and within environments that are more geographically dispersed.

FDDI specifies the physical and media-access portions of the OSI reference model. FDDI is not actually a single specification, but it is a collection of four separate specifications, each with a specific function. Combined, these specifications have the capability to provide high-speed connectivity between upper-layer protocols such as TCP/IP and IPX, and media such as fiber-optic cabling. FDDI’s four specifications are the Media Access Control (MAC), Physical Layer Protocol (PHY), Physical-Medium Dependent (PMD), and Station Management (SMT) specifications.

The MAC specification defines how the medium is accessed, including frame format, token handling, addressing, algorithms for calculating cyclic redundancy check (CRC) value, and error-recovery mechanisms. The PHY specification defines data encoding/decoding procedures, clocking requirements, and framing, among other functions. The PMD specification defines the characteristics of the transmission medium, including fiber-optic links, power levels, bit-error rates, optical components, and connectors.

The SMT specification defines FDDI station configuration, ring configuration, and ring control features, including station insertion and removal, initialization, fault isolation and recovery, scheduling, and statistics collection. FDDI is similar to IEEE 802. 3 Ethernet and IEEE 802. 5 Token Ring in its relationship with the OSI model. Its primary purpose is to provide connectivity between upper OSI layers of common protocols and the media used to connect network devices. Figure 8-3 illustrates the four FDDI specifications and their relationship to each other and to the IEEE-defined Logical Link Control (LLC) sublayer.

FDDI defines four types of devices: single-attachment station (SAS), dual-attachment station (DAS), single-attached concentrator (SAC), and dual-attached concentrator (DAC). An SAS attaches to only one ring (the primary) through a concentrator. One of the primary advantages of connecting devices with SAS attachments is that the devices will not have any effect on the FDDI ring if they are disconnected or powered off. Concentrators will be covered in more detail in the following discussion. Each FDDI DAS has two ports, designated A and B. These ports connect the DAS to the dual FDDI ring.

Therefore, each port provides a connection for both the primary and the secondary rings. As you will see in the next section, devices using DAS connections will affect the rings if they are disconnected or powered off. An FDDI concentrator (also called a dual-attachment concentrator [DAC]) is the building block of an FDDI network. It attaches directly to both the primary and secondary rings and ensures that the failure or power-down of any SAS does not bring down the ring. This is particularly useful when PCs, or similar devices that are frequently powered on and off, connect to the ring.

FDDI provides a number of fault-tolerant features. In particular, FDDI’s dual-ring environment, the implementation of the optical bypass switch, and dual-homing support make FDDI a resilient media technology. When the ring is wrapped, the dual-ring topology becomes a single-ring topology. Data continues to be transmitted on the FDDI ring without performance impact during the wrap condition. When a single station fails, devices on either side of the failed (or powered-down) station wrap, forming a single ring. Network operation continues for the remaining stations on the ring. When a cable failure occurs, devices on either side of the cable fault wrap. Network operation continues for all stations. It should be noted that FDDI truly provides fault tolerance against a single failure only.

When two or more failures occur, the FDDI ring segments into two or more independent rings that are incapable of communicating with each other. Optical Bypass Switch An optical bypass switch provides continuous dual-ring operation if a device on the dual ring fails. This is used both to prevent ring segmentation and to eliminate failed stations from the ring. The optical bypass switch performs this function using optical mirrors that pass light from the ring directly to the DAS device during normal operation.

If a failure of the DAS device occurs, such as a power-off, the optical bypass switch will pass the light through itself by using internal mirrors and thereby will maintain the ring’s integrity. The benefit of this capability is that the ring will not enter a wrapped condition in case of a device failure.

Preamble

  • Gives a unique sequence that prepares each station for an upcoming frame. Start delimiter
  • Indicates the beginning of a frame by employing a signaling pattern that differentiates it from the rest of the frame. Frame control
  • Indicates the size of the address fields and whether the frame contains asynchronous or synchronous data, among other control information.

Destination address

  • Contains a unicast (singular), multicast (group), or broadcast (every station) address. As with Ethernet and Token Ring addresses, FDDI destination addresses are 6 bytes long. Source address
  • Identifies the single station that sent the frame. As with Ethernet and Token Ring addresses, FDDI source addresses are 6 bytes long.

Data

  • Contains either information destined for an upper-layer protocol or control information. Frame check sequence (FCS)
  • Is filed by the source station with a calculated cyclic redundancy check value dependent on frame contents (as with Token Ring and Ethernet).
  • The destination address recalculates the value to determine whether the frame was damaged in transit. If so, the frame is discarded.

End delimiter

Contains unique symbols; cannot be data symbols that indicate the end of the frame.

Frame status

Allows the source station to determine whether an error occurred; identifies whether the frame was recognized and copied by a receiving station.

Like FDDI, CDDI provides data rates of 100 Mbps and uses dual-ring architecture to provide redundancy. CDDI supports distances of about 100 meters from desktop to concentrator. CDDI is defined by the ANSI X3T9. 5 Committee. The CDDI standard is officially named the Twisted-Pair Physical Medium-Dependent (TP-PMD) standard. It is also referred to as the Twisted-Pair Distributed Data Interface (TP-DDI), consistent with the term Fiber Distributed Data Interface (FDDI). CDDI is consistent with the physical and media-access control layers defined by the ANSI standard.

Review Questions

  • What are the benefits of using FDDI instead of CDDI?
  • What role does the DAC play in the FDDI network?

Cite this Page

Fddi and Cddi. (2018, Jan 26). Retrieved from https://phdessay.com/fddi-and-cddi/

Don't let plagiarism ruin your grade

Run a free check or have your essay done for you

plagiarism ruin image

We use cookies to give you the best experience possible. By continuing we’ll assume you’re on board with our cookie policy

Save time and let our verified experts help you.

Hire writer