EFFICIENT Building Services
Introduction
The freshly constructed T2 Inspection Facility is located within Dubai’s Jebel Ali Port‘s Container Terminal 2. The edifice has five chief installations including particular review installation, detained stuff warehouse, Canis familiaris pace, usage review installation, and municipality review installation. The edifice was completed in the twelvemonth April 2013.
Order custom essay Efficient Building Services with free plagiarism report
The review installation is used for general review of lading come ining or go forthing the state. It has a 1.35-meter steel platform from the finish floor degree associated with dock leveler with a hinged lab isolation platform ( LIP ) concrete incline. The installation has hot rolled subdivisions with aluminum roof cladding scaling a tallness of 8.15 metre. Besides, the review installation has an opaque aluminum fencing around it with a tallness of 2 metres from the top of the platform.
The detained stuff installation is to keep stuffs illicitly transported through the airdrome. The detained stuff warehouse occupied the land and first floors. It has a medium coating with ceramic flooring tiles for office country. The floor and wall tiles in wet countries have sixty square inch ceiling. Internal wall are painted with washable emulsion pigment for easiness in cleansing. Like the review installation, it has a platform with a tallness of 1.35 metre from finish floor degree associated with dock leveler with hinged LIP platform size concrete incline and concrete stairss. It besides has steel construction with a built up country of 732.0 m2and entire tallness of 9.20 metre, hot rolled subdivisions with aluminum roof facing and vision panels at roof. Besides, the installation has a hydraulic lift and steel stairway to ease entree to the edifice. The installation has a block walls for office, larder and lavatories.
The Canis familiaris pace has a built up country of 65.70 m2and entire tallness of 5.35 metre. It has a medium coating with ceramic flooring tiles for dry countries with 60 square inches ceiling tiles. The floor and wall tiles for wet countries have sixty square inches H2O opposition ceiling tiles. The internal walls are coated with washable emulsion pigment while the exterior lifts and sunning zones are coated with epoxy pigment.
The imposts review installation has a 1.35-meter platform from finish floor degree associated with dock leveler with hinged LIP platform size and concrete inclines. The installation has an office edifice with a built up country of 515 m2and entire tallness of 5.4 metre with hot rolled subdivisions with strengthened concrete slab. The floors have a medium coating with ceramic flooring tiles for dry countries the same size as the other installations ( 60 square inches ) . Wet countries have H2O immune tiles. The installation has block walls with washable emulsion pigment for internal walls. To heighten the lighting of the edifice, the roof has aluminium cladding with vision panels.
The municipality review facility’s office edifice has a built up country of 800 m2and entire tallness of 5.0 metre. It has hot rolled subdivisions with strengthened concrete slab. Medium finish with ceramic flooring tiles for dry countries with 60X60 false ceiling tiles, floor & A ; wall tiles for wet countries with 60X60 H2O opposition false ceiling tiles. It besides has block walls with washable emulsion pigment for internal walls.
Main installations offered in the edifice
Electrical system
The edifice has a substation providing low electromotive force electricity into the edifice. It has one low electromotive force panel with seven Sub Main Distribution Boards. The system has on capacitance bank and eight poles light. It besides has backup generator for supplying electricity in times of breaks in brinies electricity. The electrical plants comply with the ordinances of Dubai Electricity and Water Authority ( DEWA ) ordinances.
The edifice has particular LED lighting through all its installations that complies with CIBSE criterions. The country around the edifice has 30-Meter high masts that light the full location. The masts are equipped with adjustable metal halide visible radiations. Besides, the masts have supports on the lantern ring for IT entree point and security cameras.
The edifice besides has power, telephone and information web canals that serve the building’s needs. The electrical canals step 150mm, telephone steps 100 millimeter, informations canals measure 100mm while security camera ducts step 100mm. Notably, power, and telephone and information web connexions to all installations in conformity with criterions laid down by the governments.
Air conditioning and airing
The edifice has a functional air airing system that complies with the American Society of Heating, Refrigerating, and Air-Conditioning Engineers ( ASHRAE ) . All stuffs used in the edifice were sourced from certified makers. The stuffs comply with international specifications. The edifice is fitted with air conditioning equipment complete with window and wall fumes canals. The system has an automatic shutter to maximise the indoor air quality. The bringing pipes are made of insulated Cu. The refrigerating pipes run on the roof and have a metal covered tray to cut down heat addition from the environment.
The air conditioning in the edifice comprises of 2 fresh air-handling units and 13 fumes fans. The system besides has a cosmetic split unit. A thermoregulator separates the split unit and the fresh air-handling unit. The FAHU runs continuously but is times to close down after having a fire dismay signal. The FAHU has an outside air and fumes dampers that remains unfastened when the system is running. These dampers stop four seconds after the supply fan Michigans.
The AC system in the edifice can present a broad temperature scope with comparative easiness of accommodation. The system besides occupies small infinite largely in the ceiling. The system’s heat recovery option besides conserves energy good as it recovers most of the heat from exhaust pipes. However, dehumidification in these systems is non as efficient given that the edifice is near a big H2O organic structure. The system is besides comparatively expensive compared to other systems and necessitate expensive care over clip. It is besides comparatively noisy ( Huchtemann & A ; Muller, 2014, p.23 ) .
Mechanical specification of the air conditioning
The air status is designed to let for DE system. This is to let the grading of the air conditioning system to cover more room in instance of enlargement or alteration of internal design. In add-on, the air conditioning system supplies treated fresh air to all suites. The exhaust pipes will hold a heat recovery mechanism to retrieve heat from the exhaust air in cold times. The Inspection bays besides have hall have air conditioning and air drapes to maximise user experience. The detained stuff warehouse has forced airing to coerce air deep into the installation ( Joo & A ; Liu, 2001 ) .
Water supply and drainage
The edifice has equal fresh H2O supply to all its floors. In add-on, the edifice has three Grass Reinforced Panel keeping armored combat vehicles with a set of electrical pumps. The armored combat vehicles store as much H2O as possible for usage in times of deficit. Water is heated utilizing 14 H2O warmers situated at assorted locations in the supply system. Storm H2O is drained through 22 soak ways designed to suit as much H2O as possible. The soak ways are designed in a aslant place to let for easy flow of H2O into the chief drain.
Fire system
The edifice has an belowground fire pipe system that is lined by cement. The pips are coated with bitumen and are made of malleable Fe in line with American Water Works Association criterions ( AWWA ) . The edifice has an A/G RCC H2O armored combat vehicle to hive away H2O as required by the relevant ordinances. In add-on, the TSE irrigation pipe extends from bing pipes from the next secret plan.
Ramps, stairwaies and Elevators
The edifice has luxuriant entree installations including inclines, stairwaies and lifts. These are stationed at strategic topographic points in the edifice to ease entree to the other degrees ( Allen & A ; Iano, 2008 ) . Most of the entree paths in the edifice are through inclines and stairwaies. However, lifts are available for usage unit of ammunition the clock and are powered by electrical motors. They contribute well to electrical ingestion in the edifice.
Other Systems
The edifice has a assortment of systems that increase the edifices atmosphere including exigency lighting, telephone systems, informations lines, photocopiers and other office machinery. These systems enhance the usage of the edifice including disposal and review services. These public-service corporations consume an estimated 5 % of the edifices electricity.
Administration Command Center
The edifice has a cardinal bid centre. This electronic platform integrates communicating and control system in the full edifice to a cardinal location for easiness in commanding and communicating ( Indraganti, et al. , 2014 ; Shah, Prajapti & A ; Patel, 2012, p.10 ) . The Centre ensures that activities in the assorted operational units are coordinated and incase of an exigency, the proper safety steps are implemented. The halfway Acts of the Apostless as a cardinal mention point for the direction of people, induction off procedures and direction of the systems. The system reduces running costs as a little staff staffs the cardinal bid. In peculiar, the bid centre manages the low electromotive force power systems, metering systems and security systems in the company. The centre besides oversees the smooth flow of operations among the assorted runing units of the terminus. Most significantly, the centre undertakes everyday preventative and disciplinary care processs to cut down possibility of accidents and malfunctions.
Technical restrictions of the edifice
The terminal 2 edifice was commissioned in 2013. The edifice boasts extremist modern installations and a beautiful coating. Compared to other edifices, the terminal 2 edifice has a better design and is more suitable for comfy usage and life. Most of the air and H2O supply canals are insulated to cut down energy loss o the environment. However, there are a figure of restrictions in its design and systems. To get down with, the edifice is non energy efficient. Energy costs of running the edifice are high. These include lighting and air conditioning. The design did non take into history factors such as possibility of natural illuming during daylight to salvage on energy costs. In add-on, the detained warehouse installation has a limited infinite and needs a batch of air circulation ensuing in monolithic usage of electricity ( Bonda & A ; Sosnowchik, 2007, p.31 ) .
In add-on, the edifice did non use equal green engineerings in the building and care of edifice installations. For case, the edifice uses electrical H2O warmers alternatively of tapping solar energy that is abundant in Dubai ( Nunnelly, 2008 ; Thomas, Zimmerman & A ; Ott, 2011, p.14 ; Kats, et al. , 2008 ; Huchtemann & A ; Muller, 2014 ) .
Decision
The T2 edifice was completed in the 2013 and has five chief installations including particular review installation, detained stuff warehouse, Canis familiaris pace, usage review installation, and municipality review installation. The review installation is used for general review of lading come ining or go forthing the state and has a tallness of 8.15 metre. The detained stuff installation holds stuffs illicitly transported through the airdrome and occupies the land and first floors. The Canis familiaris pace has a built up country of 65.70 m2and entire tallness of 5.35 metre and is used a meat for sniffer Canis familiariss. The imposts review has an office edifice with a built up country of 515 m2and entire tallness of 5.4 metre with hot rolled subdivisions with strengthened concrete slab. The municipality review facility’s office edifice has a built up country of 800 m2and entire tallness of 5.0 metre. It has hot rolled subdivisions with strengthened concrete ( Lee & A ; Guerin, 2010 ) .
The edifice has equal supply of fresh H2O to all its floors complete with storage armored combat vehicles. However, while the edifice boasts extremist modern installations and a beautiful coating, it lags behind modern design in energy preservation. The energy costs of running the edifice are high including lighting, warming and air conditioning. The design failed to see usage of natural illuming during daylight to salvage on energy costs. In add-on, the edifice uses electrical H2O warmers alternatively of tapping solar energy that is abundant in Dubai.
Mentions
Joo, I. , Liu, M. ( 2001 ) . Performance Analysis of Dual-Fan, Dual-Duct Constant Volume Air Handling Units. Cover Art:1stInternational Conference for EnhancedConstructing Operations- ICEBOTexas A & A ; M University. 16-19 July. Accessed
9 February 2012 from the nexus hypertext transfer protocol: //repository.tamu.edu
Nunnelly, R. ( 2008 ) . Design or operations issue? .Engineered System.Vol. 1. ( 1 ) :13.
Shah, P. , Prajapti, D. Patel, M. ( 2012 ) . Overview of industrial filtration engineering and its applications.Indian Journal of Science and Technology[ online ] . Vol.
3. ( 10 ) .
Thomas, Z. , Zimmerman, M. , Ott, A. ( 2011 ) . Next-Generation Building Energy Management Systems and Implications for Electricity Markets.U.S. Departmentof EnergyVol. 1. ( 14 ) . Accessed 9 February 2012 from the nexus hypertext transfer protocol: //www.osti.gov/bridge
Bonda, P. , Sosnowchik, K. ( 2007 ) .Sustainable commercial indoor. New Jersey: John
Wiley & A ; Sons
Kats, G. , Alevantis, L. , Berman, A. , Mills, E. , Perlman, J. ( 2008 ) The Cost and Financial Benefits of Green Buildings. Hoboken, New Jersey: John Wiley & A ; Sons Inc.
Allen, E. , Iano, J. ( 2008 ) . Fundamentalss of constructing building: stuffs and methods. Hoboken, New Jersey: John Wiley & A ; Sons Inc.
Lee, Y. , Guerin, D. ( 2010 ) . Indoor environmental quality differences between office types in LEED-certified edifices in the US.Building and Environment. Vol.45 ( 5 ) : 1104–1112
Indraganti, M. , Ooka, R. , Rijal, H. , Brager, G. ( 2014 ) . Adaptive theoretical account of thermic comfort for offices in hot and humid climes of India.Building and Environment.Vol. 74: 39–53
Huchtemann, K. , Muller, D. ( 2014 ) . Combined simulation of a deep land beginning heat money changer and an office edifice.Building and Environment.Vol. 73: 97–105
Cite this Page
Efficient Building Services. (2018, Sep 03). Retrieved from https://phdessay.com/efficient-building-services/
Run a free check or have your essay done for you